UPS Trifásico MY Series Online UPS 10~40kVA
MODEL | MY10 | MY20 | MY30 | MY40 | ||||||
Input | ||||||||||
Voltage (Vac) | 80-280 (L-N)/138-485 (L-L) | 138-485 (L-L) | ||||||||
Frequency (Hz) | 40-70 | |||||||||
Power Factor | ≥0,99 | |||||||||
THDi | <3% (Carga Lineal) | |||||||||
Output | ||||||||||
Capacity (VA) | 10 | 20 | 30 | 40 | ||||||
AC/AC Efficiency (Max.) | 96% | |||||||||
Power Factor | 1.0 | |||||||||
Voltage (Vac) | 220/230/240±1% (L-N) 380/400/415±1%(L-L) | |||||||||
Frequency (Hz) | 50/60±0,1 (modo batería) | |||||||||
THDv | ≤2% (carga lineal), ≤4% (carga no lineal) | ≤1% (carga lineal), ≤4% (carga no lineal) | ||||||||
Battery | ||||||||||
Voltage (Vdc) | ±192 (±96~±240 ajustable) | ±192 (±144~±240 ajustable)* | ||||||||
BATT Type | 16~40*9AH/12V | 24~40*9AH/12V | 48~80*9AH/12V | |||||||
Charger Current (A) Max. | 1-10 configurable | 1-20 configurable | ||||||||
Other | ||||||||||
Communication Interface | RS485+EPO+Contacto seco (1 entrada, 5 salidas)(SNMP son opcionales en la ranura) | |||||||||
LCD Display | Pantalla Táctil de 4,3 Pulgadas + LED + Botones físicos | |||||||||
Alarm | Baja batería, entrada CA anormal, falla de UPS, etc. | |||||||||
Protection | Baja batería, sobrecarga, cortocircuito y sobretemperatura, etc. | |||||||||
Noise (dB) | <55 | |||||||||
Working Temperature (℃) | -5~40 | |||||||||
Relative Humidity | 0~95%, sin condensación | |||||||||
Dimension (W×D×H) mm | 250×755×880 | 300×785×1250 | ||||||||
Weight (kg) | 98 (20 ×9AH) | 132 (32×9AH) | 240 (64×9AH) | 240 (64×9AH) |
UPS Modular MR33A Series (20~240kVA)
Advanced Technology:
- Online Double Conversion
- Fully DSP control
- N+X parallel technology
- 3 level inverter technology
- DC startup function
- Frequency converter function
- Advanced power module dormancy technology
Excellent Flexibility:
- Intelligent battery management
- Flexible network management
Green Power:
- Wide input voltage range
- PCB boards feature with anti-corrosion paint coating
- Internal maintenance bypass
- Allow 100% three phase unbalance load
- ECO mode and EPO function
- Module communication ring connection redundancy design
- Self-aging test function
UPS Monofásico KR11 Plus Series Online UPS 1~10kVA
MODEL | KR1000+/ KR1000L+ | KR2000+/ KR2000L+ | KR3000+/ KR3000L+ | KR6000+/ KR6000L+ | KR1110S+/ KR1110+ |
Input | |||||
Voltage (Vac) | 120~295 | 80~275 | |||
Frequency (Hz) | 50/60± 10% (50/60Hz auto-sensing) | ||||
Power Factor | ≥0.99 | ||||
THDi | <5% | ||||
Output | |||||
Capacity (VA) | 1000 | 2000 | 3000 | 6000 | 10000 |
AC/AC Efficiency (Max.) | 92% (94.2% optional) | 93% (94.6% optional) | 94% (94.2% optional) | 95% | 95% |
Power Factor | 0.9 (1.0 optional) | ||||
Voltage (Vac) | 208/220/230/240±1%(selectable on display panel) | ||||
Frequency (Hz) | 50/60±0.2% (battery mode) | ||||
THDv | THD < 2% (linear load ); THD < 5% (nonlinear load ) | THD < 1% (linear load ); THD < 4% (nonlinear load ) | |||
Transfer Time | 0 | ||||
Battery | |||||
Voltage (Vdc) | 24 or 36/36 | 48 or 72/72 | 72 or 96/96 | 192/192~240 | 192/192~240 |
BATT Type | 2×9Ah/12V or 3×7Ah/12V/ External | 4×9Ah/12V or 6×7Ah/12V/ External | 6×9Ah/12V or 8×7Ah/12V/ External | 16×7Ah/12V/ External 16~20 units settable | 16×9Ah/12V/ External 16~20 units settable |
Charger Current (A) Max. | 1/4 | 1/4 | 1/4 | 1~8 (adjustable) | 1~8 (adjustable) |
Other | |||||
Communication Interface | RS232, EPO, USB (slot) (SNMP, RS485+dry contact are optional in slot) | ||||
LCD Display | AC input & output voltage, frequency, Load level, Battery level, Temperature; AC mode, Battery mode, Bypass mode, and Fault | ||||
Alarm | Low battery, abnormal AC input, UPS failure, etc. | ||||
Protection | Low battery, overload, short-circuit and over temperature, etc. | ||||
Noise (dB) | <50 | <55 | |||
Working Temperature (℃) | -5 ~ 40 | ||||
Relative Humidity | 0 ~ 95%, No condensation | ||||
Dimension (W×D×H) mm | 145×360×225 | 190×400×330 | 230×502×553/190×422×337 | ||
Weight (kg) | 9.2 or 11.6 or 4.5 | 17.7 or 22.4 or 8.5 | 22.9 or 27.6 or 9.2 | 54.5/10.9 | 56.2/12.5 |
UPS FR-UK33 Series Online UPS (10~600kVA)
Main Features
- Online double conversion
- IGBT inverter and output isolation transformer
- Wide input voltage range
- 3 phases UPS allow 100% unbalance load
- Fully DSP control, high reliability and performance
- DC cold start function
- Advanced battery charging management
- Intelligent fan speed control
- HMI-touch screen display
- ECO mode and EPO
- ECO-mode with 98% efficiency
- 10,000 events logs
- Battery self-test function
- Intelligent RS232/RS485,DB9 dry contact communication port
- 10-30kVA models with wheels
- MODBUS &SNMP adapter(optional)
- Advanced no-master-slave parallel technology (optional)
- Intelligent battery monitor system-MMBM(optional)
- 12 Pulse rectifier(optional)
- Bypass isolation transformer(optional)
Application
- Computer room
- Data center
- Precision instrument
- Intelligent equipment
- Industrial application