Mostrando los 5 resultados

UPS Trifásico 40 – 120kVA 3:3

MODEL KUE-3T40 -NB KUE-3T60 -NB KUE-3T80 -NB KUE-3T120 -NB
INPUT
Rated voltage 380 / 400 / 415 Vac
Frequency range 40 ~ 70 Hz
Power factor ≥ 0,99
Bypass voltaje range - 60% ~ +20% (settable)
OUTPUT
Voltage 380 / 400 / 415 Vac
Voltage regulation ± 1%
Frequency Synchronized with utility in mains mode, 50/60 Hz ± 0.1% in battery mode
Power factor 1
THDV ≤ 1% (linear load), ≤ 5% (non – linear load)
BATTERIES
DC voltage ± 192 Vdc (± 180 ~ ± 276 Vdc settable)
Charging current (max.) 12 A 24 A 36 A
Recharger time Dependo n the capacity of battery
OTHERS
Dimensiones (W x D x H) (mm) 360 x 850 x 950 360 x 850 x 1200 440 x 850 x 1200
Operating Temperature 0°C ~ 40°C
Altitude ≤ 1000 m; above 1000m, downgrading 1% for each additional 100m
 

UPS Trifásico W 10 KVA – 30KVA

MODEL W10K W15K W20K W30K
INPUT
Rated voltage 380 / 400 / 415 Vac
Frequency range 40-70
Power factor > 0,99
Bypass voltaje range -20 % ~ +15% Up limited_+10%, +15%, +20%, +25%. Down limited: -10%, -15%, -20%,-30%,-40%,
OUTPUT
Voltage 380/400/415 Vac
Voltage regulation ± 1%
Frequency Synchronized with utility in mains mode, 50/60 Hz ± 0.1 % in battery mode
Power factor 1
THDV ≤ 1%  (full linear load), <3% (Full non-linear load according to IEC/EN62040-3)
BATTERIES
DC voltage ± 120  VDC  (20 PCS) ± 240 VDC (40 PCS) ± 240 VDC (40 PCS) ± 180 VDC (60 PCS)
Charging current 10A max
Recharger time Estándar model: 90% capacity restored in 8 hours, Long time model: depend on the capacity of battery.  
OTHERS
Dimensiones (W x D x H) (mm) 250 x 750 x 560 (S) 250 x 750 x 560 (H) 250 x 800 x 700 (S) 250 x 720 x 560 (H) 250 x 840 x 930 (S) 250 x 840 x 650 (H)
Operating Temperature 0°C ~ 40°C
Altitude ≤ 1000 m, Load derated 1% per 100m from 1000 – 2000m

UPS Trifásico MY Series Online UPS 10~40kVA

MODEL MY10 MY20 MY30 MY40
Input
Voltage (Vac) 80-280 (L-N)/138-485 (L-L) 138-485 (L-L)
Frequency (Hz) 40-70
Power Factor ≥0,99
THDi <3% (Carga Lineal)
Output
Capacity (VA) 10 20 30 40
AC/AC Efficiency (Max.) 96%
Power Factor 1.0
Voltage (Vac) 220/230/240±1% (L-N) 380/400/415±1%(L-L)
Frequency (Hz) 50/60±0,1 (modo batería)
THDv ≤2% (carga lineal), ≤4% (carga no lineal) ≤1% (carga lineal), ≤4% (carga no lineal)
Battery
Voltage (Vdc) ±192 (±96~±240 ajustable) ±192 (±144~±240 ajustable)*
BATT Type 16~40*9AH/12V 24~40*9AH/12V 48~80*9AH/12V
Charger Current (A) Max. 1-10 configurable 1-20 configurable
Other
Communication Interface RS485+EPO+Contacto seco (1 entrada, 5 salidas)(SNMP son opcionales en la ranura)
LCD Display Pantalla Táctil de 4,3 Pulgadas + LED + Botones físicos
Alarm Baja batería, entrada CA anormal, falla de UPS, etc.
Protection Baja batería, sobrecarga, cortocircuito y sobretemperatura, etc.
Noise (dB) <55
Working Temperature (℃) -5~40
Relative Humidity 0~95%, sin condensación
Dimension (W×D×H) mm 250×755×880 300×785×1250
Weight (kg) 98 (20 ×9AH) 132 (32×9AH) 240 (64×9AH) 240 (64×9AH)

UPS Modular MR33A Series (20~240kVA)

Advanced Technology:

  • Online Double Conversion
  • Fully DSP control
  • N+X parallel technology
  • 3 level inverter technology
  • DC startup function
  • Frequency converter function
  • Advanced power module dormancy technology

Excellent Flexibility:

  • Intelligent battery management
  • Flexible network management

Green Power:

  • Wide input voltage range
  • PCB boards feature with anti-corrosion paint coating
  • Internal maintenance bypass
  • Allow 100% three phase unbalance load
  • ECO mode and EPO function
  • Module communication ring connection redundancy design
  • Self-aging test function

UPS FR-UK33 Series Online UPS (10~600kVA)

Main Features

  • Online double conversion
  • IGBT inverter and output isolation transformer
  • Wide input voltage range
  • 3 phases UPS allow 100% unbalance load
  • Fully DSP control, high reliability and performance
  • DC cold start function
  • Advanced battery charging management
  • Intelligent fan speed control
  • HMI-touch screen display
  • ECO mode and EPO
  • ECO-mode with 98% efficiency
  • 10,000 events logs
  • Battery self-test function
  • Intelligent RS232/RS485,DB9 dry contact communication port
  • 10-30kVA models with wheels
  • MODBUS &SNMP adapter(optional)
  • Advanced no-master-slave parallel technology (optional)
  • Intelligent battery monitor system-MMBM(optional)
  • 12 Pulse rectifier(optional)
  • Bypass isolation transformer(optional)

Application

  • Computer room
  • Data center
  • Precision  instrument
  • Intelligent equipment
  • Industrial application